Created on 06/17/2015
c
2015 Sun Hydraulics Corporation See www.sunhydraulics.com for detailed product information 1 of 2
MODEL
NQEB
Air bleed and start-up valve
SERIES 2 / CAPACITY: 15 - 200 L/min. / CAVITY: T-3A
Air-bleed and start-up cartridges are used to purge air trapped in the system to help reduce power requirements
and facilitate pump priming during the start-up of blocked center circuits.
TECHNICAL DATA
Maximum Operating Pressure 350 bar
Seal kit - Cartridge Buna: 990-203-007
Seal kit - Cartridge Polyurethane: 990-003-002
Seal kit - Cartridge Viton: 990-203-006
(X)CONTROL
X Not Adjustable
(A)ADJUSTMENT RANGE
A -
(N)SEAL MATERIAL
N Buna-N
V Viton
MATERIAL/COATING
Standard Material/Coating
/AP Stainless Steel, Passivated
/LH Mild Steel, Zinc-Nickel
snhy.com/NQEB
TECHNICAL FEATURES
Air-bleed and start-up valves require a minimum of 4 gpm (15 L/min.) flow rate and 80 psi (5,5 bar) system pressure.
The valve will re-open when system pressure falls below 25 psi (1,7 bar)
After air has been purged, closing times vary from approximately 12 seconds at 4 gpm (15 L/min.) to 0.5 seconds at 50 gpm 200 L/min.).
Incorporates the Sun floating style construction to minimize the possibility of internal parts binding due to excessive installation torque and/or cavity/cartridge
machining variations.
PERFORMANCE CURVES
Model Code Example: NQEBXANCONFIGURATION OPTIONS
Created on 06/17/2015
c